HIGHLIGHTS

> Construction as per IEC 61000-4-4 Ed.3
> EFT/Burst Testing of Signal- and Datalines
> Active Coupling Length 1 m
> Permissable Burst Voltage 7 kV
> For Cable Diameter up to 40 mm

paypal
visa
mastercard
american express
unionpay
Share:

Shipping & Delivery

Products are shipped internationally from Shenzhen / Dongguan, China.
Standard export terms are FOB Shenzhen / Dongguan

(Incoterms®).
Under FOB terms, the seller completes export customs clearance and delivers the goods to the port of shipment.
The buyer is responsible for international freight, insurance, import customs clearance, and final delivery.
Alternative shipping arrangements can be discussed based on customer requirements.

FOR TESTS ACCORDING TO

> IEC 61000-4-4
> EN 61000-4-4
> IEC 61000-4-18
> EN 61000-4-18

APPLICATION AREAS

Industry, Telecom, Medical, Residential, Broadcast

PRODUCT DATA

Technical Data

Max Voltage: 7.0 kV
Dimension: 140 mm x 1000 mm
Coupling Plate Height: GND – couplingplate, 100 mm
Connector: High voltage connector, coaxial
GND Connection: 4 mm plug, banana
EUT Cable: Up to 40 mm diameter
Weight: 10.6 kg

General Data

Temperature: 10°C to 40°C
Rel.Humidity: Max. 85 %, non condensing
Atmospheric Pressure: 86 kPa (860 mbar) to 106 kPa (1,060 mbar)

COUPLING CLAMP CALIBRATION

The calibration of the capacitive coupling plane is performed with the open circuit voltage setting at the EFT/burst generator (50 ohm output): 2,000 V
Resulting output voltage across the PVF 50 (50ohm matching resistor): 1,000 V
Measuring voltage Vm: 10 V
Measured voltage considering the 50 ohm input impedance of the oscilloscope: 5 V
Resulting attenuation (theoretical): 400:1